Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MLC 500 | ||||||
Device type | Transmitter | ||||||
Cascading | Guest | ||||||
Contains | 2x BT-NC sliding block | ||||||
Application | Danger zone guarding, Access guarding, Hand protection | ||||||
Characteristic parameters | |||||||
Type | 4, IEC/EN 61496 | ||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Protective field data | |||||||
Resolution | 40 mm | ||||||
Protective field height | 1,500 mm | ||||||
Operating range | 0 ... 20 m | ||||||
Optical data | |||||||
Number of beams | 60 Piece(s) | ||||||
Light source | LED, Infrared | ||||||
LED light wavelength | 940 nm | ||||||
Mean power of transmitter diode | 50 µW | ||||||
Transmitted-signal shape | Pulsed | ||||||
LED group | Exempt group in acc. with EN 62471:2008 | ||||||
Connection | |||||||
Number of connections | 1 Piece(s) | ||||||
Connection 1 | |||||||
Type of connection | Cable with connector | ||||||
Function | Cascade, Host In, Cascade, Middle Guest In | ||||||
Cable length | 330 mm | ||||||
Sheathing material | PUR | ||||||
Cable color | Black | ||||||
Wire cross section | 0.14 mm² | ||||||
Thread size | M12 | ||||||
Type | Male | ||||||
Material | Plastic | ||||||
No. of pins | 8 -pin | ||||||
Number of connections | 1 Piece(s) | ||||||
Mechanical data | |||||||
Dimension (W x H x L) | 29 mm x 1,514 mm x 53 mm | ||||||
Housing material | Metal, Aluminum | ||||||
Lens cover material | Plastic / PMMA | ||||||
Material of end caps | Diecast zinc | ||||||
Net weight | 1,623 g | ||||||
Housing color | Yellow, RAL 1021 | ||||||
Type of fastening | Groove mounting, Mounting bracket, Swivel mount | ||||||
Environmental data | |||||||
Ambient temperature, operation | 0 ... 55 °C | ||||||
Ambient temperature, storage | -30 ... 70 °C | ||||||
Relative humidity (non-condensing) | 0 ... 95 % | ||||||
Certifications | |||||||
Degree of protection | IP 65 | ||||||
Protection class | III | ||||||
Certifications | TÜV Süd, c CSA US, c TÜV NRTL US | ||||||
Vibration resistance | 50 m/s² | ||||||
Test procedure for oscillation in accordance with standard | IEC/EN 60068-2-6 | ||||||
Shock resistance | 100 m/s² | ||||||
Test proce |